ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 84
the correct cable (typically the manufacturer’s modem cable). If you still receive no response, refer to the
modem manufacturer’s troubleshooting guide.
Once you have established communications with your modem, you need to change the settings listed in
the following table. Give the commands in the order listed, with each command followed by {ENTER}.
Coastal Environmental Systems typically uses one of three following modems: the US Robotics Sportster,
the Zoom Pocket FaxModem, and the IDC MOM14400. If you have a different modem, some of the
commands may differ from those given below.
Setting
US Robotics
Sportster
Zoom Pocket FaxModem and
IDC MOM14400
Baud (or bit) rate fixed at 9600 AT&N6 ATN0, ATF8 or ATS37=9
Auto-Answer On ATS0=1
Suppress result codes* ATQ1*
DCD follows remote carrier AT&C1
Echo off ATE0
Save settings to non-volatile
RAM
AT&W0
ATY0
*WARNING!
The configuration must be slightly different if you are dialing out from the
ZENO
®
-3200 using an alarm message. To dial out, you must enable a
restricted set of result codes. Use commands ATQ0 followed by ATX, rather
than ATQ1, in this case.
The following DIP switches need to be set on the US Robotics Sportster for consistency with the above
settings.
102
1 2 3* 4 5 6 7 8
Up
Down
Figure 6-2. DIP switch settings for US Robotics Sportster telephone modem.
102
Black fields symbolize the positions of each DIP switch.