Seitenansicht 212
ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 205
11. ALARM MESSAGES
Coastal Environmental Systems
ZENO
®
-3200 User Manual
One of the most important features of the ZENO
®
-3200 is its ability to transmit unsolicited alarm
messages.
A regular output message is transmitted by the ZENO
®
-3200 on a regular
schedule.
But an alarm message is transmitted when a specific condition occurs, which
makes them completely asynchronous.
An alarm condition is defined by configuring the appropriate processes,
especially Alarm Processes. The alarm condition can be based upon more
than one requirement.
Once the alarm condition is met, the ZENO
®
-3200 can transmit an alarm
message via any of the following:
• Simple terminal • Radio link • Telephone modem
• Cellular modem or • GOES radio.
An alarm condition can also be used to turn on (or off) a digital output or a
switched voltage.