Page 203
Time :10 :15 :20 :25 :30 :35 :40: 45 :50 :55 :00 :05 :10 :15 :20 :25 :30 :35 :40: 45 :50 :55
(minutes)
ZENO
Message #1
Message #2
Message #3
Message #4
To set up this sampling scheme, the Sample Period Menu of the User Menu will require the following
values:
The Sample Interval time will be 1800 seconds, or 30 minutes
The Sample Duration time will be 60 seconds
The Sample Offset will be zero––sampling starts at the beginning of each half-hour period
The four Data Output Message Periods will then take the following values as shown in the table below. It
is worth noting that message numbers 1, 3 and 4 are given the same data output message period, but only
message #1 interprets 0 to mean “output at the end of the sampling period.”
Message Number Data Output Message Period
#1 (output at the end of the 1 minute sampling period) 0
#2 (output at the end of the half-hour) 300 seconds (5 minutes)
#3 (output when triggered by an alarm) 0
#4 (not used) 0
10.8. RESETTING (REBOOTING) THE ZENO
®
-3200
After you have made changes to your configuration, it may be a good idea to reboot the ZENO
®
-3200 to
ensure that everything has been properly initialized.
Before you reboot the ZENO
®
-3200, make sure that you save your
configuration to EEPROM! Otherwise, the changes you made will be lost.
There are two ways you can reboot the ZENO
®
-3200:
Turn off the power, wait a few seconds, then turn it on again.
Use menu option R in the Zeno Program Menu.