ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-10
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) 1
c2/1
Item 3: Field Name rh
c3/rh
Item 4: Data Process Record P1.1
3
c4/P1.1
3
Item 5: Field Decimal Places 0 DEFAULT
Item 6: Field Width 3
c6/3
Item 7: Data Storage Class Code 7: Compressed Floating Point (2)
c7/7
DEFAULT = Default Data: it is not necessary to enter a command for this Item.
3 This data will vary depending on the number of sensors being connected to the ZENO
-3200.
* Refer to the Sensor Manual for Signal Names
7. 100 PLATINUM RTD
SENSOR MENU
Settings for RTD Probe
ITEM DATA
COMMAND ENTERED
Item 1: Sensor Type code = 3 (18-bit Differential A to D)
c1/3
Item 2: Sensor Name = RTD
c2/RTD
Item 3: Sensor Input Channel = 1
c3/1
Item 4: Analog Channel Gain = 1 DEFAULT
Item 5: Analog Channel Attenuation = 1 DEFAULT
Item 6: Switched Power code = 0 (NO SWITCHED POWER) DEFAULT
Item 7: Sensor Excitation Voltage = 1 (EXC = 1.25 VDC)
c7/1
Item 8: Switched Excitation Return = A
c8/A
Item 9: Sensor Warm up Time = 0 DEFAULT
Item 10: Sensor Sample Count = 1 DEFAULT
Item 11: Maximum Sensor Readings = 0 DEFAULT
Item 12: Sensor Timing Loop = 2
c12/2
Item 13: Conversion Coefficient A = 0 DEFAULT
Item 14: Conversion Coefficient B = 1 DEFAULT
Item 15: Conversion Coefficient C = 0 DEFAULT
Item 16: Retry count = N/A N/A
N/A = These ITEMS are not applicable for this sensor.
DEFAULT = Default Data, it is not necessary to enter a command for this Item.
Settings for Temperature-Stable 1-kΩResistor