ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 41
> C4/S1
PROCESS MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Process Items for Record 1 of 1:
Item 1: Process Category 1 : General
Item 2: Process Number 2 : Averaging Process
Item 3: User-defined Process Name AvgTemp
Item 4: Input for Average Data S1 : IntTemp
>
You should notice that the Sensor Name "IntTemp" that was specified in Sensor Record #1 is displayed
when you reference Sensor Record #1.
The user specified name given to a Sensor Record or Process Record is
displayed when that particular record is referenced.
When you leave the Zeno Program Menu and the ZENO
®
-3200 starts collecting and processing data,
Process Record #1 will calculate the average of the data collected by Sensor Record #1, the Internal
Temperature Sensor. You are now done defining this Process Record definition.
If you want to see what values are calculated by the Averaging Process that you defined in Process
Record #1, you can obtain help about the process by typing the command HP1{ENTER}.
39
Your screen
will look something like this:
> HP1
Process Record 1 specifies the Averaging Process Type.
The Averaging Process produces the following
floating-point output values:
1 : Average Data, current value = 0.
2 : Most Recent Sample, current value = 0.
3 : Standard Deviation, current value = 0.
4 : Maximum Value, current value = 0.
5 : Minimum Value, current value = 0.
The Averaging Process produces the following
error output values:
E1 : Process Error Code, current value = 1.
Hit any key to continue . . .
As shown, the Averaging Process does a lot more than just calculate the average. It also calculates the
standard deviation, the maximum and minimum values seen during the Sample Duration and a Process