ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 112
Regional Processing Centers (RPC) are located worldwide in the United States, Japan and Australia for
local data recovery.
6.8.4. Connecting The Telonics ST-13 ARGOS PTT With The ZENO
®
-3200
Coastal Environmental Systems uses the Telonics ST-13 ARGOS transmitter, normally with the TTL
standard interface.
The ST-13 port labeled ARGOS RADIO is connected to the ZENO
®
-3200 DE-25 port labeled AUX
SERIAL DATA, using the specialized interface provided by Coastal Environmental Systems. This
interface includes the power supplied to the ARGOS transmitter.
Figure 6-10. Telonics ST-13 to ZENO
®-
3200 block diagram.
The ZENO
®
-3200 provides 12 VDC unregulated power to the ST-13 over this cable. The interface box
also includes a lithium battery to provide backup power to the ST-13, in case the ZENO
®
-3200 should
lose power for any reason.
6.8.5. ZENO
®
-3200 Configuration
The ZENO
®
-3200 supports ARGOS radio communications on COM2. The first step in configuring a
ZENO to transmit using the ARGOS transmitter is to set COM2 accordingly. From the User Menu, enter
C to reach the COMMUNICATIONS menu. Set the COM2 port type to ARGOS, and the COM2 baud rate
to 1200 or 9600 (to match the ST-13 baud rate).
You can attach both an ARGOS radio and serial sensors to COM2.