ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 201
REMEMBER: the ZENO
®
-3200 will automatically transmit output
messages only when they have not been suppressed by the Real Time Output
Format, found on Line Item #4 in the System Functions Menu.
227
If you specify a time in seconds, for the Sample Interval, that exceeds the length of the Sample Interval,
the ZENO
®
-3200 will transmit the output message at the end of the Sample Interval.
If no time is specified for Output Message #1 (Line Item #5 would be set at 0), which is the default output
message, the ZENO
®
-3200 will automatically transmit Output Message #1 at the end of the Sample
Duration.
The ZENO
®
-3200 will only automatically and regularly transmit Output
Messages #2, #3 and #4 when a non-zero time is specified in their respective
Line Items (#6, #7 and #8) in the Output Message Timing Menu.
This DOES NOT include transmission of any of these messages when
configured to transmit as an asynchronous alarm message using one of the
Alarm Processes.
228
Any output message can be automatically transmitted on a regular schedule and be transmitted as an
asynchronous Alarm Message.
229
Regular logging of data is ALWAYS done at the end of the Sample Duration
regardless of the settings for output message timing in the Output Message
Timing Menu.
When you configure the ZENO
®
-3200 to transmit an output message several
times during a Sample Interval, you are viewing snapshots of the current
states of any referenced sensor or process data.
Any output messages transmitted prior to the end of the Sample Duration do
not necessarily contain the same data that will be logged at the end of the
Sample Duration.
Here are a few examples that demonstrate output message timing.
Example #1
Here are a few possibilities that demonstrate how can Output Message #1 be configured to transmit in
accordance with the Sample Interval.
Output Message #1 can be synchronized with the end of the Sample Duration simply by setting Line
Item #5 in the Output Message Timing Menu to 0. If the Sample Interval is set to 30 minutes and the
227
Refer to Section 4.4.2.
228
Refer to Section 11.
229
Refer to Section 11.