ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-24
ITEM DATA
COMMAND ENTERED
Item 1: Sensor Type code = 16 (General Serial Script)
c1/16
Item 2: Sensor Name = Init425
c2/Init425
Item 3: Sensor Input Channel = COM2
c3/COM2
Item 6: Switched Power code = 0 DEFAULT
Item 9: Sensor Warm up Time = 0 DEFAULT
Item 10: Sensor Sample Count = 1 DEFAULT
Item 11: Maximum Sensor Readings = 1
C11/1
Item 12: Sensor Timing Loop = 1 (0.5 seconds) DEFAULT
Item 16: Retry Count = 0 DEFAULT
Item 17: Sensor Address = 0 DEFAULT
Item 18: Sensor Port Type = RS485
C18/RS485
Item 19: Sensor Baud Rate = 1200
C19/1200
Item 20: Sensor Bits Per Character = 7
C20/7
Item 21: Sensor Parity = E
C21/E
Item 22: Sensor Start Bits = 1 DEFAULT
Item 23: Sensor Stop Bits = 1 DEFAULT
Item 24: Sensor GSI Script Number = 1 DEFAULT
Item 25: Sensor Data Collection Control = P3.1 : AddFlag
3
C25/P3.1
3
DEFAULT = Default value: it is not necessary to enter a command for this item.
3 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
GENERAL SERIAL SCRIPT MENU
Settings to Initialize Vaisala 425AH Sensor on COM2
LINE DATA
Line 1 STRING 1 ( 50 )
Line 2 SEND "\B "
Line 3 WAIT 75
Line 4 SEND "%1sXH1!", sID
Line 5 RECEIVE 500, "%s", S1
Line 6 SEND "\B "
Line 7 WAIT 75
Line 8 SEND "%1sXU1!", sID
Line 9 RECEIVE 500, "%s", S1
Line 10 SEND "\B "
Line 11 WAIT 75
Line 12 SEND "%1sXQ1;3.3;3;0005!", sID
Line 13 RECEIVE 500, "%s", S1