ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 182
A Data Output Record is an individual data field to be transmitted in an
output message or logged in a Data Record and is defined in the Data
Output Menu.
Data Output Records can be subdivided into three different field type categories:
Field types that transmit information or data only
Field types that log data into ZENO
®
-3200 memory only
Field types that both log and transmit data
If no Data Output Records specify a field type that logs data, then no data
will be logged by the ZENO
®
-3200.
Any time one or more data is logged, the ZENO
®
-3200 always logs the Time
Stamp as the first four bytes of the Data Record.
The order of the Data Output Records that log data defines the order of the
data fields within the Data Record.
As an example, you have a configuration that contains 15 Data Output Records, of which Data Output
Records #5, #8 and #12 are the only ones that log data. The Data Record will consist of four data fields:
the Time Stamp, followed by the data referred to by Data Output Records #5, #8 and #12 respectively. If
you were to go the Data Retrieval Menu
206
to retrieve the logged data, you will retrieve Data Records
consisting of those four data fields.
The data content and length of each Data Record is the SAME!
You cannot configure different Data Records of different lengths!
If more than one Output Message contains fields that log data, each logged
Data Record will contain ALL of the logged data from ALL of the output
messages in the order of the Data Output Records!
206
Refer to Section 4.