ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 154
Simple on/off status
Period of streaming digital pulses
Frequency of streaming digital pulses
Count streaming digital pulses
Read a digital encoder
For any digital sensor, the valid voltage range is 0.0 to 5.0 VDC. Any
voltage below 2.0 VDC is regarded as an OFF state and any voltage above
2.5 VDC is regarded as an ON state.
Setting the sensor type and the channel, to read the digital sensor through, are set via Line Items #1 and
#3 in the Sensor Menu for the particular Sensor Record. These are summarized in the following table:
Sensor Type
Code
(Line Item #1)
Name
Available Channels
(Line Item #3)
4 Digital Period Measurement, f > 10 kHz
5
Digital Frequency Measurement, f > 10
kHz
6 Digital Period Measurement, f < 10 kHz
7
Digital Frequency Measurement, f < 10
kHz
8 Digital State Measurement
9 Digital Edge Counter
10 through 23
10 Tipping Bucket 24
14 Differential Encoder
10 through 23; requires 2 adjacent
channels.
The specifics of each digital sensor type is summarized in the following table: