ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page D-46
5.7. Divide Two Data Values Process
Inputs: 4 Dividend (D)
5 Divisor (D)
Outputs: 1 The quotient of dividing the dividend by the divisor
E1 Process Error Code
5.8. Quadratic Process
Inputs: 4 Data X (D)
5 Quadratic coefficient A (U)
6 Quadratic coefficient B (U)
7 Quadratic coefficient C (U)
Outputs: 1 The result y calculated from quadratic equation y = Ax
2
+ Bx + C
E1 Process Error Code
5.9. Invert Data Value Process
Inputs: 4 Data X (D)
Outputs: 1 The result from inverting the input data value (1/X)
Assumptions: If Data X is 0, the result will be set to a Bad Sensor Value.
E1 Process Error Code
5.10. Raise Data To Power Process
Inputs: 4 Data X (D)
5 Constant Exponent Value Y (U)
Outputs: 1 The results from raising the Data X to the exponential value, X
Y
E1 Process Error Code
5.11. Add Multiple Data Values Process
Inputs: 4-11 Data1 through Data8 (All D)
Outputs: 1 The numerical sum of all 8 inputs
E1 Process Error Code
5.12. Sixth-order Polynomial Process
Inputs: 4 Data X (D)
5 Coefficient a
6 (U)
6 Coefficient a
5 (U)
7 Coefficient a
4 (U)
8 Coefficient a
3 (U)
9 Coefficient a
2 (U)
10 Coefficient a
1 (U)
11 Coefficient a
0 (U)
Outputs: 1 The value of the sixth-order polynomial applied to x
E1 Process Error Code
This process calculates the sixth-order polynomial a
6
x
6
+ a
5
x
5
+ a
4
x
4
+ a
3
x
3
+ a
2
x
2
+ a
1
x + a
0
.