ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-10
ZENO
®
-3200 number 134 to change the sample period to 30 seconds would require the following
command:
#01340001SETPARAM1,30,34^C
To instruct the same ZENO
®
-3200 to change the compass offset to negative 16 degrees would require the
following command:
#01340001SETPARAM19,-16,40^C
ZENOSOFT
®
will respond with a CCSAIL OK if the parameter can be changed successfully.
ZENOSOFT
®
will respond with a CCSAIL ERROR 6 if run-time parameter nnn is not valid.
ZENOSOFT
®
will respond with a CCSAIL ERROR 7 if run-time parameter nnn is valid, but data value
xxxxx is out of range.
ZENOSOFT
®
will respond with CCSAIL ERROR 8 if run-time parameter nnn cannot be changed.
These include the following run-time parameters:
21 Clock processor speed (generally set to 16777)
22 System read/write parameter (generally set to 1)
24 ADC significant bits (18/13)
37 ADC quiet mode (generally set to 0)
43 Not used
44 Not used
47 Not used
48 Not used
50 Not used
51 Not used
Additionally, before setting any of the following parameters, the user must send the
ENDSAMPLE
command (see below). This command instructs the ZENO
®
-3200 to cease sampling.
4 Sensor timing loop #2 in half-seconds
5 Sensor timing loop #3 in half-seconds
6 Sensor timing loop #4 in half-seconds
23 ADC noise rejection frequency (50/60 Hz)
25 Output message #1 period in half-seconds (0 = directly after data sampling)
26 Output message #2 period in half-seconds (0 = not transmitted)
27 Output message #3 period in half-seconds (0 = not transmitted)
28 Output message #4 period in half-seconds (0 = not transmitted)
29 Output message #1 COM port (0=COM1; 1=COM2; 2=COM3)
30 Output message #2 COM port (0=COM1; 1=COM2; 2=COM3)
31 Output message #3 COM port (0=COM1; 1=COM2; 2=COM3)
32 Output message #4 COM port (0=COM1; 1=COM2; 2=COM3)
34 ADC values output in volts or counts? (0 = VOLTS, 1 = COUNTS)
35 Time crystal calibration offset (generally 0)
36 Time crystal calibration base frequency
65 12-bit ADC correction factor (10,000)