Page 36
> C1/1 C2/Battery C3/BATT C12/2
SENSOR MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Sensor Items for Record 2 of 2:
Item 1: Sensor Type Code 1 (12-bit Analog to Digital)
Item 2: Sensor Name Battery
Item 3: Sensor Input Channel BATTERY VOLTAGE
Item 6: Switched Power Code 0 (NO SWITCHED POWER)
Item 7: Sensor Excitation Voltage Code 0 (NO EXCITATION VOLTAGE)
Item 8: Switched Excitation Return 0
Item 9: Switched Power Warmup Time 0
Item 10: Sensor Sample Count 1
Item 11: Maximum Sensor Readings 0
Item 12: Sensor Timing Loop 2 (1.0 seconds)
Item 13: Conversion Coefficient A 0
Item 14: Conversion Coefficient B 1
Item 15: Conversion Coefficient C 0
Item 17: No. of Additional 15-msec Delays 0
>
The two sensors that needed to be configured for our example are now done.
When you have reached a milestone during the configuration process, it is a good idea to save the
configuration to EEPROM in case there is a power surge. To do this, return to the Zeno Program Menu
by typing the command Z{ENTER} in the Sensor Menu. Once back in the Zeno Program Menu, type the
command E{ENTER}. Once you have done that, you will see something like this on your screen:
> e
Verifying parameters can be stored in EEPROM . . .
Saving parameters to EEPROM . . .
Saving sensor lists to EEPROM . . .
Saving process lists to EEPROM . . .
Saving data output lists to EEPROM . . .
Saving repeater lists to EEPROM . . .
Saving general serial scripts to EEPROM . . .
Saving constants to EEPROM . . .
665 out of 2048 bytes used in EEPROM.
Total EEPROM Writes = 151, EEPROM Checksum = 102.
ZENO PROGRAM MENU
(S) Sensor Menu (M) Memory Management Menu
(P) Process Menu (W) Password Menu
(D) Data Output Menu (R) Reset System
(T) Sensor Timing Loop Menu (E) Save Parameters To EEPROM
(O) Output Message Timing Menu (U) User Menu
(L) System Load Menu (Q) Quit
(G) General Serial Script Menu (H) Help
>
Kommentare zu diesen Handbüchern