ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 14
After you connect your ZENO
®
-3200 to your computer and apply power (as described in Section ), you
will see the start-up message on your terminal emulation program, followed by a set of measurements
generated once a minute. The screen will look something like this:
Watchdog Reset
Please wait.../
ZENO-3200 using ZENOSOFT V1.964 Jun 28 2001 15:41:01 CS 96CC
(C)opyright 1995-2001, Coastal Environmental Systems, Seattle, WA, USA.
System Time = 01/07/11 13:47:31
Initializing Zeno 3200 .../
Zeno 3200 is Data Sampling. Type 'U'{ENTER} to access the User Interface.
01/07/11,13:48:55,22.7,13.8,
01/07/11,13:49:55,22.9,13.8,
01/07/11,13:50:55,23.0,13.8,
01/07/11,13:51:55,23.2,13.8,
Each data message contains the following comma delimited fields:
The date and time when the measurement was completed, usually called the timestamp (here, the
afternoon of July 11, 2001).
Two data values: the average internal temperature and average battery voltage.
14
As this example shows, the ZENO
®
-3200 can output data messages giving measured data values in real
time as well as log the data. Up to four different messages can be defined, each containing different
values, outputted at different times and routed to different ZENO
®
-3200 COM ports.
In our example, the ZENO
®
-3200 is outputting the data messages on COM3. If you enter the User
Interface via COM3, any real time data messages routed to COM3 will be interrupted; but messages to
other COM ports (if any) as well as data logging will not be affected.
The ZENO
®
-3200 continues to log data records in real time while you view
data records via the User Menus.
(If you enter the Zeno Program Menus, the ZENO
®
-3200 will suspend all
data collection and logging.)
To view the logged data records, you first need to enter the User Menu of the ZENO
®
-3200 User
Interface.
To enter the User Menu, type U followed by the {ENTER} key in your
terminal emulation program.
Upon entering the User Menu, the ZENO
®
-3200 will stop sending real-time data messages to your
terminal emulation program and, instead, it will display the User Menu. Your screen will look something
like this.
14
Since many ZENO
®
-3200s are factory-configured by Coastal Environmental Systems prior to delivery, the
messages sent to your terminal emulation program are likely to differ in the number, type, and format of the
measured values.