ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page D-9
Assumptions: Null inputs are not processed
The Multiple Input Minimum/Maximum Process returns the maximum and minimum values of the up to
eight inputs to the process.
1.12. Previous Sample Data Process
Inputs: 4 Any sensor, process or constant output.
Outputs: 1 Most recent data
2 Second most recent data
3 Third most recent data
4 Fourth most recent data
5 Fifth most recent data
6 Sixth most recent data
7 Seventh most recent data
8 Eighth most recent data
L1 Most recent long integer data
L2 Second most recent long integer data
L3 Third most recent long integer data
L4 Fourth most recent long integer data
L5 Fifth most recent long integer data
L6 Sixth most recent long integer data
L7 Seventh most recent long integer data
L8 Eighth most recent long integer data
E1 Process error code
Assumptions: None
The Previous Sample Data Process saves the inputted data at the end of the Sample Interval and shifts the
data collected in the previous Sample Interval down one output until the eighth output is reached. Hence,
the process stores a single data value for up to eight consecutive Sample Intervals. The stored data can be
retrieved as either a floating-point value or a long integer value.
1.13. Multiple Data Validation Process
Inputs: 4 Control Data = any sensor, process or constant output
5-16 Data 1 through Data 12 = any sensor, process or constant output.
Outputs: 1-12 Validated Data 1 through Data 12 (respectively) or all BSV
E1 Process error code
Assumptions: None
The process takes one control data input and 12 other data inputs. When the control data is 0, each of the
twelve Validated Data outputs will be the same as their corresponding non-control data inputs. When the
control data is not 0, all twelve Validated Data outputs will be Bad Sensor Values (BSV =
-1,000,000.0).
1.14. Single Data Validation Process
Inputs: 4 Control Data = any sensor, process or constant output
5 Data any sensor, process or constant output
Outputs: 1 Validated Data
E1 Process error code