ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-20
COMMANDS TO ENTER
I1 C1/STRING 4 ( 90, 1, 2, 4 )
I2 C2/FLOAT 9
I3 C3/RECEIVE 1000, "%s", S1
I4 C4/SEND "FL\r"
I5 C5/WAIT 10
I6 C6/RECEIVE 5000, "%s", S1
I7 C7/RECEIVE 0, "%s,%f,%f,%f,%f,%f,%f,%f,%f,%s,%f,%s,", S2, F1, F2, F3, F4, F5, F6, F7, F8, S3, F9,
S4
MEMORY MANAGEMENT MENU
ITEM DATA
COMMAND ENTERED
Item 1: COM1 GSI Memory Size in Bytes = 0 DEFAULT
Item 2: COM2 GSI Memory Size in Bytes = 100
C1/100
Item 3: COM3 GSI Memory Size in Bytes = 0 DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
PROCESS MENU
Settings for First Cloud Level
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 3 : Alarm
C1/3
Item 2: Process Type code = 8 : Missing Sensor Data Process
C2/8
Item 3: User-defined Process Name = 3 : noceil1
c3/noceil1
Item 4: Input for Sensor Data S1.3 : ceil
1
C4/S1.3
1
Item 5: Default Data -1
C5/-1
Item 6: Digital Output Channel 0 DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
1 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 1 : General DEFAULT
Item 2: Process Type code = 9 : Collect Process
C2/9
Item 3: User-defined Process Name = 3 : cld1col
c3/cld1col
Item 4: Input for Sensor Data P1.2 : noceil1
2
C4/P1.2
2
DEFAULT = Default value: it is not necessary to enter a command for this item.
2 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
Kommentare zu diesen Handbüchern