ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 163
Sensor Type
Code
(Line Item #1)
Name
Available Channels
(Line Item #3)
11 Serial Compass
12 CCSAIL Sensor
15 GPS Receiver
16 General Serial Script Sensor (USI)
COM1, COM2, COM3, TTL or
COMPASS (depending upon sensor
requirements)
19 Asynchronous CCSAIL Sensor
COM1, COM2 or COM3 (but not
specified using Line Item #3)
13 SDI-12 Sensor
17 Continuous SDI-12 Sensor
18 Concurrent SDI-12 Sensor
COM2 or COM3
For wiring information to each COM port, refer to Section 13.4.
Specifying Number of Serial Sensor Data Fields
Most serial sensors output more than one data field in their data messages. for some serial sensors, the
number of data fields is known, but some require the user to specify how many data fields are to be
received from the sensor. This is summarized in the following table:
Sensor Type
Number of Data Fields
Code
(Line Item #1)
Name
Number
Where Specified
11 Serial Compass 1 N/A
12 CCSAIL Sensor
19 Asynchronous CCSAIL Sensor
Variable Line Item #10
15 GPS Receiver 15 N/A
16
General Serial Script Sensor
(USI)
Variable
USI
13 SDI-12 Sensor
17 Continuous SDI-12 Sensor
18 Concurrent SDI-12 Sensor
Variable Line Item #10
CCSAIL and SDI-12 sensors require that you specify the number of received data fields using Line Item
#10, the Sample Count. General Serial Script Sensors are different in that the USI script defines the
number and type of data fields that are to be received from the sensor.
181
Specifying Sensor Address
181
Refer to Section 12.2.