General Serial Script Sensor Specifics (USI)
A full explanation of the USI is presented in Section 12.2. This sensor type is used when no other
specific serial sensor type can collect data from a serial sensor.
10.3.5. Configuring A Serial Sensor
Four Line Items in the Sensor Menu are required to be configured for any serial sensor. Use of the other
9 Line Items depends upon the sensor type and collection requirements.
Line Item #1: Sensor Type Mandatory
Line Item #3: Channel Mandatory
Line Item #10 Sample Count Any CCSAIL or SDI-12 Sensor
Line Item #16: Retry Count Optional
Line Item #17: Depends on the Sensor Type Depends on the Sensor Type
Line Item #18: Sensor Port Type. Mandatory
Line Item #19: Sensor Baud Rate. Mandatory
Line Item #20: Sensor Bits Per Character General Serial Script Sensor Only
Line Item #21: Sensor Parity General Serial Script Sensor Only
Line Item #22: Sensor Start Bits General Serial Script Sensor Only
Line Item #23: Sensor Stop Bits General Serial Script Sensor Only
Line Item #24: Sensor GSI Script Number General Serial Script Sensor Only
Line Item #25: Sensor Data Collection Control General Serial Script Sensor Only
Channel Selection and Communications Settings
You must identify the communications interface required by your serial
sensor to select the correct channel because each channel supports a finite
number of port types.
If you don't set up the communications interface correctly, the ZENO
®
-3200
won't be able to collect data from the serial sensor.
Each channel supports the following baud rates:
300, 600, 1200, 2400, 4800, 9600, 19200
The port types available for each channel are listed in the following table: