ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 130
Figure 6-11. Speech interface wiring diagram.
6.12. OPTIONAL ACCESS CONTROL CUSTOMIZATION TO THE USER
INTERFACE
The Communications Menu contains two extra Line Items that are optionally accessible to the user.
These extra Line Items are displayed below:
COMMUNICATIONS MENU
(Cn/m) Change Item n To Value m (R) Repeater Menu
(M) Modem Menu (Tn) Terminal Mode On COM Port n
(P) Power Control Menu (E) Save Parameters To EEPROM
(G) GOES Menu (U) User Menu
(A) ARGOS Menu (Q) Quit
(D) Digital Control Menu (H) Help
Item 1: 2400 (COM1 Baud Rate)
Item 2: 2400 (COM2 Baud Rate)
Item 3: 9600 (COM3 Baud Rate)
Item 4: RS232 (COM1 Port Type)
Item 5: RS232 (COM2 Port Type)
Item 6: RS232 (COM3 Port Type)
Item 7: COM1,COM2 (COM Ports to Exclude from User Interface)
Item 8: NO (Enable Exclusive CCSAIL Access)
>
Line Item #7 provides a means to exclude specific communications ports from having access to the User
Interface.