Seitenansicht 304
ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page D-1
D. ZENO
®
-3200 PROCESS
LIBRARY
Coastal Environmental Systems
ZENO
®
-3200 User Manual
This appendix lists all the processes, their inputs and outputs. The process outputs are meaningful
throughout the sample interval times -- for example, averages are maintained throughout, rather than
being calculated at the end of the sample duration.
Enter HPTn.m to obtain help on Process Type number m in Category n.
Bad Sensor Values (BSV)
305
are NOT processed, including any process that
requires cumulative data in its calculations.
1. GENERAL PROCESSES CATEGORY
1.1. Immediate Data Process
Inputs: 4 Any sensor or process output
Outputs: 1 The most recent value
E1 Process Error Code
Assumptions: None.
Each time the Immediate process is called, it simply moves the data value from the input into its own
output data address.
1.2. Averaging Process
Inputs 4 Any sensor or process output
Outputs 1 Average value
2 The most recent input value
3 Standard deviation
4 Maximum value
5 Minimum value
E1 Process Error Code
Assumptions: None.
305
Refer to Section 10.4.5.