ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-3
ITEM DATA
COMMAND ENTERED
Item 1: Sensor Type code = 2 (18-bit Single-Ended A to D)
c1/2
Item 2: Sensor Name = analog
c2/analog
Item 3: Sensor Input Channel = 1+
c3/1+
Item 4: Analog Channel Gain = 1
c4/1
Item 5: Analog Channel Attenuation = 10
c5/10
Item 6: Switched Power code = 0 (NO SWITCHED POWER) DEFAULT
Item 7: Sensor Excitation Voltage = 0 (NO EXCITATION) DEFAULT
Item 8: Switched Excitation Return = NONE DEFAULT
Item 9: Sensor Warm up Time = 0 DEFAULT
Item 10: Sensor Sample Count = 1 DEFAULT
Item 11: Maximum Sensor Readings = 0 DEFAULT
Item 12: Sensor Timing Loop = 2
c12/2
Item 13: Conversion Coefficient A = 0 DEFAULT
Item 14: Conversion Coefficient B = 3
c14/3
Item 15: Conversion Coefficient C = 0 DEFAULT
PROCESS MENU
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 1 : General DEFAULT
Item 2: Process Type code = 2 : Averaging Process
c2/2
Item 3: User-defined Process Name = 3 : AvgAnlg
c3/AvgAnlg
Item 4: Input for Relative Humidity = S1 : analog
1
c4/S1
1
DEFAULT = Default Data, it is not necessary to enter a command for this Item.
1 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
DATA OUTPUT MENU
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1
c2/1
Item 3: Field Name = AvgAnlg
c3/AvgAnlg
Item 4: Data Process Record = P1.1
2
c4/P1.1
2
Item 5: Field Decimal Places = 1
c5/1
Item 6: Field Width = 4
c6/4
Item 7: Data Storage Class Code = 8:Floating Point (4)
c7/8
2 This data will vary depending on the number of sensors being connected to the ZENO
.