OUTPUT MESSAGE TIMING MENU
(Cn/m) Change Item n To Value m (H) Help
(Z) Zeno Program Menu
Item 1: COM3 (Data Output Message #1 COM Port)
Item 2: COM1 (Data Output Message #2 COM Port)
Item 3: COM3 (Data Output Message #3 COM Port)
Item 4: COM3 (Data Output Message #4 COM Port)
Item 5: 30.0 (Data Output Message #1 Period)
Item 6: 30.0 (Data Output Message #2 Period)
Item 7: 0.0 (Data Output Message #3 Period)
Item 8: 0.0 (Data Output Message #4 Period)
Item 9: 0 (Record Counter Starting Value)
Item 10: 0 (Record Counter Reset Value)
>
As shown, each message output is configured to a specific COM port.
10.7.1. Selecting the Communications Port for Each Output Message
Line Items #1 through #4 of the Output Message Timing Menu allow you to specify a COM port from
which the ZENO
®
-3200 will transmit each output message respectively. Each Line Item can be set to one
of three values: COM1, COM2, or COM3.
More than one output message can be transmitted on a single
communications port.
The port type and baud rate for each of the selected communications ports
are the same as those specified in the Communications Menu.
225
10.7.2. Specifying the Time of Transmission for Each Output Message
Line Items #5 through #8 of the Output Message Timing Menu allow you to specify when the ZENO
®
-
3200 will transmit each of the four output messages within the Sample Interval
. The value set for each
Line Item is the number of seconds into the Sample Interval
that the output message is to be
transmitted.
226
The valid range of values for each of Line Items #5 through #8 is from 0 to 86400 at
increments of 0.5 seconds.
225
Refer to Section 6.1.
226
For information about the Sample Interval, refer to Section 3.1.3.