ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 107
For the Campbell Scientific SAT HDR GOES transmitter, set the COM2 port type to CGOES, and the
COM2 baud rate to 9600.
You can attach both a GOES radio and sensors to COM2 as long as they are
not on the same pins!
Set the Communications Menu line items to match the GOES.
COMMUNICATIONS MENU
(Cn/m) Change Item n To Value m (Tn) Terminal Mode On COM Port n
(M) Modem Menu (E) Save Parameters To EEPROM
(P) Power Control Menu (U) User Menu
(G) GOES Menu (Q) Quit
(D) Digital Control Menu (H) Help
Item 1: 9600 (COM1 Baud Rate)
Item 2: 1200 (COM2 Baud Rate)
Item 3: 9600 (COM3 Baud Rate)
Item 4: RS232 (COM1 Port Type)
Item 5: GOES (COM2 Port Type)
Item 6: RS232 (COM3 Port Type)
>
Next, type G{ENTER} from the Communications Menu to enter the GOES Menu.
GOES MENU
(Cn/m) Change Item n to Value m (E) Save Parameters To EEPROM
(D) Run GOES Diagnostics (U) User Menu
(R) Reset GOES Errors (Q) Quit
(I) Initialize GOES (H) Help
Item 1: ce587a74 (Data Collection Platform Address)
Item 2: 52 (Self-Timed Transmit Channel Number)
Item 3: 00:04:00:00 (Self-Timed Transmission Interval)
Item 4: 02:09:00 (Self-Timed Transmission Offset)
Item 5: 1 (Transmission Window Length, in Minutes)
Item 6: SHORT (Satellite Link Parameter: Preamble)
Item 7: 128 (Random Transmit Channel Number)
Item 8: 00:15:00 (Random Transmission Interval)
Item 9: 01:05:00 (Random Disable Time)
Item 10: 1200 (GOES Bit Rate)
Item 11: NONE (GOES Interleaver)
>
Set the GOES Menu line items as follows:
Specify the Data Collection Platform Address, Line Item #1. This is a hex value.