ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 54
You would type the command L5{ENTER} in the Data Retrieval Menu and your display will look
something like this:
DATA RETRIEVAL MENU
(A) Show Records AFTER Specified Time (F) Flash Memory Information
(B) Show Records BETWEEN Timespan (D) Delete All Data Records
(Ln) Show LAST n Records (N) Number of Records Logged
(*) Show ALL Data Records (U) User Menu
(@n) Show n Unmarked Records (Q) Quit
(M) Mark Recently Shown Data (H) Help
(C) Compute Data Logging Capacity
Precede Any "Show Data" Command With An 'X' for X-Modem Transfer
(e.g. Enter 'X*' To Send All Data Sets Via X-Modem)
> L5
Hit The Space Bar To Halt The Log Data Output.
DATE TIME AvgTemp AvgBatt
01/07/31 07:54:55 22.0 13.8
01/07/31 07:55:55 22.0 13.8
01/07/31 07:56:55 22.1 13.8
01/07/31 07:57:55 22.2 13.8
01/07/31 07:58:55 22.3 13.8
The displayed Data Record format (e.g., whether comma or space separation between the data values is
used) can be changed from the System Functions Menu.
4.1.3. Viewing & Marking The Oldest Data Records
Option “@ in the Data Retrieval Menu shows up to "n" oldest, unmarked Data Records. This option is
very similar to the "L" option but shows the oldest and unmarked Data Records as opposed to the most
recently logged Data Records. After you have viewed the oldest Data Records using the “@ option, you
can "mark" them as having been read by typing M{ENTER} in the Data Retrieval Menu.
If you mark the most recently viewed oldest Data Records, you cannot view
them again using the @ option; but you can still view them using other data
retrieval options.
The next time you enter the @n command, ZENOSOFT
®
will display the next oldest unmarked n records.
Here is something you can try, to understand how the marking mechanism works:
View the 5 oldest unmarked Data Records by typing @5{ENTER} in the Data Retrieval Menu.
Repeat the previous command and you will view the same oldest Data Records.
Now type M{ENTER} to mark the viewed oldest Data Records.
View the 5 oldest unmarked Data Records again, and you will see that they are the next 5 oldest Data
Records as previously viewed.