ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 125
OUTPUT MESSAGE TIMING MENU
(Cn/m) Change Item n To Value m (H) Help
(Z) Zeno Program Menu
Item 1: COM3 (Data Output Message #1 COM Port)
Item 2: COM2 (Data Output Message #2 COM Port)
Item 3: COM3 (Data Output Message #3 COM Port)
Item 4: COM3 (Data Output Message #4 COM Port)
Item 5: 0.0 (Data Output Message #1 Period)
Item 6: 0.0 (Data Output Message #2 Period)
Item 7: 0.0 (Data Output Message #3 Period)
Item 8: 0.0 (Data Output Message #4 Period)
Item 9: 0 (Record Counter Starting Value)
Item 10: 0 (Record Counter Reset Value)
>
The output message that is actually spoken by the ZENO
®
-3200 is the output message assigned to the
COM port connected to the modem/speech interface. for example, if the modem/speech interface port is
COM2 and Data Output Message #2 is to be spoken, then type the command C2/COM2{ENTER} in the
Output Message Timing Menu. The Data Output Message Period
148
should be set to 0 so that the
message is not transmitted automatically by the ZENO
®
-3200.
To create a spoken output message, add Data Output Records from the Data Output Menu and designate
them to apply to the same Data Output Message number that you specified in the Output Message Timing
Menu for the speech interface. The Data Output Menu is accessible from the Zeno Program Menu by
typing the command D{ENTER}.
149
To specify the text to be spoken in addition to the actual data, configure one or more Data Output Records
to be Literal String Fields.
150
It is likely that many Data Output Records will be configured as Literal
String Fields because each one is limited to holding up to ten characters in Line Item #3, the Field Name.
Continuing with the previous example, set the Literal String Field to be transmitted as part of Data Output
Message #2 so that it will be part of the spoken message:
148
The Data Output Message Period defines how often that particular output message is to be automatically
transmitted by the ZENO
®
-3200. Refer to Section 10.7.
149
Refer to Section 10.6.
150
A Literal String Field is created in a Data Output Record by setting Line Item #1 to a field code of 6. Refer to
Section 10.6.5.