ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 210
11.3.1. Selecting The Communications Port To Transmit The Alarm Message
If you have created a unique alarm message as a separate output message, you can transmit it on a
different communications port from your regular output message. To do this, follow the instructions in
Section 10.7.1.
You can configure your regular output message to be transmitted as an
alarm message on a different communications port as your regular message.
To do this, set Line Item #2 in all Data Output Records to include the output
message numbers of both the regular output message and the alarm
message.
11.3.2. Dialing-out An Alarm Message Via A Telephone Or Cellular Modem
The ZENO
®
-3200 will perform the following actions when an alarm condition occurs if properly
configured for a telephone or cellular modem:
1. The ZENO
®
-3200 will dial-out the first telephone numbers configured in the Modem Menu. If no
connection is made, it will dial-out the second telephone number and so on until a successful
connection is established. Each telephone number will be dialed up to three times before the ZENO
®
-
3200 stops the dial-out attempt.
2. Once a successful connection is established, the ZENO
®
-3200 transmits the alarm output message
specified by the Dial-out Alarm Process.
3. The ZENO
®
-3200 then hangs up the telephone or cellular modem connection.
To configure the ZENO
®
-3200 to dial-out and transmit an alarm message on a telephone modem or
cellular modem, follow this procedure:
Follow the procedures to set up telephone modem communications
238
or cellular modem
communications
239
.
Follow the recommended procedures to define an alarm condition and create an alarm message, in
Sections 11.1 and 11.2 respectively.
Designate which output message is the alarm message using a Dial-out Alarm Process
240
.
Select which communications port (COM1, COM2 or COM3) through which the ZENO
®
-3200 will
transmit the alarm message using the Output Message Timing
241
.
238
Refer to Section 6.4.
239
Refer to Section 0.
240
Refer to Section 11.3.
241
Refer to Section 11.3.1.
Seitenansicht 217