ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 81
USER MENU
(C) Communications Menu (T) Test Menu
(F) System Functions Menu (Z) Zeno Program Menus
(S) Sample Period Menu (H) Help
(D) Data Retrieval Menu (Q) Quit
>
To set up the ZENO
®
-3200 for telephone modem operation, type C{ENTER} to enter the
Communications Menu. You will see the following menu items.
> C
COMMUNICATIONS MENU
(Cn/m) Change Item n To Value m (R) Repeater Menu
(M) Modem Menu (Tn) Terminal Mode On COM Port n
(P) Power Control Menu (E) Save Parameters To EEPROM
(G) GOES Menu (U) User Menu
(A) ARGOS Menu (Q) Quit
(D) Digital Control Menu (H) Help
Item 1: 9600 (COM1 Baud Rate)
Item 2: 9600 (COM2 Baud Rate)
Item 3: 9600 (COM3 Baud Rate)
Item 4: RS232 (COM1 Port Type)
Item 5: RS232 (COM2 Port Type)
Item 6: RS232 (COM3 Port Type)
>
The relevant parameters needed to configure the desired COM port for telephone modem operation are
the following.
Set the baud rate to 9600 Baud
Set the port type to RS232
Coastal Environmental Systems recommends that you NOT change the
Baud rate while communicating via a modem.
98
Changes to communications settings should be done over a direct terminal
connection.
Next, type M{ENTER} to go from the Communications Menu to the Modem Menu. You will see the
following menu items.
98
If you cannot communicate with a ZENO
®
-3200 following a change in communications settings, the ZENO
®
-
3200 will restore the previous communication settings after 24 hours. Refer to Section 6.1.