ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-6
PROCESSING MENU
ITEM DATA
COMMAND ENTERED
Item 1: Process Category code = 1 (general)
c1/1
Item 2: Process Type code = 1 (immediate)
c2/1
Item 3: User-defined Process Name = 3 : Current
c3/Current
Item 4: Sensor Input Channel = S1.1
3
current
c3/S1.1
3
3 This value will vary depending on the number of sensors being connected to the ZENO
-3200. To output
multiple values, repeat this menu as required. You can also refer directly to the sensor outputs, rather than
going through a process. In this case, enter S1.1 (for example to obtain the value output by the 1
st
defined
sensor.
DATA OUTPUT MENU
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = cur
c3/cur
Item 4: Data Process Record = P1.1
4
c4/P1.1
4
Item 5: Field Precision = 1
c5/1
Item 6: Field Width = 6
c6/6
Item 7: Data Storage Class Code = 8 : Compressed Float
c7/8
DEFAULT = Default Data, it is not necessary to enter a command for this Item.
4 This value will vary depending on the number of sensors being connected to the ZENO
-3200. To output
multiple values, repeat this menu as required. You can also refer directly to the sensor outputs, rather than
going through a process. In this case, enter S1.1 (for example to obtain the value output by the 1
st
defined
sensor.
Wiring Connections for 4 - 20 mA current loop interface.
1. 4 - wire sensor