ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 188
Instead, you need to specify which Data Output Field Type to use to
determine whether you want the data logged.
Data is only logged at the end of a Sample Duration, not necessarily when an
output message is sent.
If Field Type Code #8 (Log Data Only) is used, specifying an output message
number does not apply.
10.6.5. The Data Output Record Field Name--A Columnar Heading Or A Literal String
Line Item #3 in the Data Output Menu specifies the user-defined Field Name for a Data Output Record.
The user-defined Field Name for any Data Output Record that logs data is
used as a columnar heading when data are retrieved in the Data Retrieval
Menu
210
.
The other primary use of the user-defined Field Name is to specify text that
will be transmitted verbatim when the Field Code for the Data Output
Record is a Literal String (Field Code #6) in the specified output message(s).
Some common uses for the Field Name when the Data Output Record specifies a Literal String are listed
below:
The name of the site where your ZENO
®
-3200 is installed
A carriage-return/line-feed ({CR}{LF}) at the start or end of each message to start a new line
The delimiting fields $ and * in two Data Output Records for use with a NMEA 0183 checksum
Sensor names or data identifiers to aid in reading a message
210
Refer to Sections 3.2.5 and 4.