Page 196
6. Create another Data Output Record after the backspace using Data Output Menu option A.
Set Line Item #1 (the Field Type Code) to 2 for an NMEA Checksum.
7. Create another Data Output Record after the NMEA checksum using Data Output Menu option A.
Set Line Item #1 (the Field Type Code) to 6 for a Literal String.
Set Line Item #3 (the Field Name) to the ASCII values for a Carriage-Return/Line-Feed,
<D><A>.
8. Go to the System Functions Menu, a submenu of the User Menu.
218
9. Set the Real Time Output Format (Line Item #4 of the System Functions Menu) to 1 for comma-
delimited data.
219
10.6.9. Conditional Message Fragments
The ZENO
®
-3200 provides the means to vary the contents of each output
message according to the actual data values using the Conditional Start &
Conditional Stop Field Type Codes in the Data Output Menu.
Conditional Start and Conditional Stop Data Output Records must be used
in pairs.
More than one pair of Conditional Start and Conditional Stop Data Output
Records can be used in a single output message, but they CANNOT be
nested or overlap.
Examples of using the Conditional Start and Conditional Stop include:
Transmitting extra data fields or text during an alarm condition.
220
Transmitting different text for different data.
221
The ZENO
®
-3200 transmits all Data Output Records contained between
Conditional Start and Condition Stop Data Output Records ONLY when the
218
Refer to Section 5.
219
Refer to Section 4.4.2.
220
Refer to Section 11.
221
This would be used extensively with the Optional Speech Interface, refer to Section 6.11.