ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page B-2
USER MENU
C COMMUNICATIONS MENU
1 Baud rate for COM 1
2 Baud rate for COM 2
3 Baud rate for COM 3
300 to 19200 baud
4 Port type of COM 1 RS232, RS232H, RADIO or TW-
RADIO
5 Port type of COM 2
RS232, RS232H, RS485, GOES,
CGOES, ARGOS
6 Port type of COM 3
RS232, RS232H, RS485, RS422* or
RS422 AND RS232*
Section 6.1
7
COM Ports to Exclude from User Interface
NONE; COM1; COM2; COM3;
COM1,COM2; COM1,COM3;
COM2,COM3
8
Enable Exclusive CCSAIL Access NO or YES
Section 6.12
Tn
Enter terminal passthrough mode to
communications port "n"
n is 1 = COM1, 2 = COM2, 3 = COM3,
or Sm, where m is Sensor Record #m
Section 6.9.1
M MODEM MENU
1 System Modem Type 0 - no modem; 1 - phone modem
2 Modem COM Port NONE, COM1, COM2 or COM3
Section 6.4.1
3 Modem Retry Period 0 to 3600
4 Modem Hang-up Delay 0 to 3600
5-8 Modem Telephone Numbers 1 through 4 Any 50-character string
Section
11.3.2
9 Modem Initialization String Any 50-character string Section 6.4.2
10 Modem Switched Voltage
- 0 (none).
- 3 (12 V, sw'd A).
- 4 (12 V, sw'd B).
- 5 (12 V, sw'd C).
- 18 to 23 (inclusive, digital outputs).
11 Modem Ring Detect Channel 0 (none), 12 to 23 (inclusive, digital
input)
Section 6.4.1
S SPEECH MENU
1 Speech Interface Installed YES or NO
2 Speech Activity Channel
3 Speech Tone Detect Channel
0 (none) or 12 to 23 (inclusive, digital
input)
4 Speech Switched Voltage
- 0 (none).
- 1 (5 V, sw'd A).
- 2 (5 V, sw'd B).
- 3 (12 V, sw'd A).
- 4 (12 V, sw'd B).
- 5 (12 V, sw'd C).
- 18 to 23 (inclusive, digital outputs).
Section 6.11
G GOES MENU
D
Run GOES DIAGNOSTICS Retrieve information from GOES radio.
R
RESET GOES errors Reset GOES radio error counter.
I
INITIALIZE GOES radio
Set the ZENO
-3200 clock to GMT &
initialize all GOES radio parameters.
1 Data Collection Platform address 8-digit HEX value
2 Self-Timed Transmit Channel Number 1 - 199
Section 6.7.6
Kommentare zu diesen Handbüchern