ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 184
10.6.3. The Different Types of Data Output Records
Line Item #1 of the Data Output Menu defines the Field Type Code of each Data Output Record. To go
to the Data Output Menu, type the command D{ENTER} from the Zeno Program Menu. A fully
configured Data Output Record could look something like this on your terminal emulation program
screen:
DATA OUTPUT MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Data Items for Record 28 of 72:
Item 1: Field Type Code 9 : Transmit and Log Data Field
Item 2: Output Message(s) 1
Item 3: Field Name heading
Item 4: Input Record P1.10 : wavg3
Item 5: Field Decimal Places 1
Item 6: Field Width 6
Item 7: Data Storage Class Code 7 : 2-byte compressed float
>
The current library of 20 different Field Type Codes (numbered 0 through 19) is summarized in the