Each COM port provides unique communications link access, which is summarized in the following
table. (For complete details about communications, refer to Section 6.)
COM1 COM2 COM3
RS232, RS232H
286
,
RADIO
287
, TW-RADIO
RS232, RS232H,
RS485, GOES
288
,
CGOES
289
, ARGOS
290
RS232, RS232H, RS485
(RS422 on Rev. D only)
13.5.1. COM3 RS232 SERIAL PORT
COM3 is the default ZENO serial port. It uses a male DE-9 connector and is wired as follows:
Figure 13-7. COM3 RS232 Serial Port Male DE-9
Connector.
The nine pins have the following functions:
286
RS232H is the ZENO
®
-3200 designation for half-duplex RS232. Refer to Section 6.1.
287
RADIO and TW-RADIO are the ZENO
®
-3200 designations for connecting a unidirectional or bi-directional
radio to COM1 via RS232. Refer to Section 6.6.
288
GOES is the ZENO
®
-3200 designation for a TTL port multiplexed to COM2 and used by the ZENO
®
-3200 for
communication with a Telonics GOES transmitter. Refer to Section 6.7.
289
CGOES is the ZENO
®
-3200 designation for a RS232 port multiplexed to COM2 and used by the ZENO
®
-3200
for communication with a Campbell Scientific GOES transmitter. Refer to Section 6.7.
290
ARGOS is the ZENO
®
-3200 designation for a TTL port multiplexed to COM2 and used by the ZENO
®
-3200 for
communication with a Telonics ARGOS transmitter. Refer to Section 6.8.