ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 131
The default ZENO
®
-3200 configuration excludes COM1 and COM2 from
the User Interface.
If you need to have full bi-directional access to the User Interface via COM1 or COM2, access to Line
Item #7 is required to change the exclusion settings.
Contact Coastal Environmental Systems if you require access to Line Items
#7 or #8 in the Communications Menu.
The options for excluding communications ports from the User Interface in Line Item #7 of the
Communications Menu are as follows:
NONE
COM1
COM2
COM3
COM1,COM2
COM2,COM3
COM1,COM3
Line Item #8 provides a means to exclude access to the User Interface via the standard U{ENTER}
command, meaning that it will only respond to CCSAIL commands. The possible values for Line Item
#8 are either NO or YES.
An example of using Line Item #8 would be when there are multiple ZENO
®
-3200s being communicated
with on a multi-drop link, such as two-way radios or RS485. In this case, it is very important that each
ZENO
®
-3200 only respond when it is specifically addressed. If the U{ENTER} command was sent on a
multi-drop line to several ZENO
®
-3200s, each ZENO
®
-3200 would respond simultaneously, which is not
desirable.