> C3/AvgTemp
PROCESS MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Process Items for Record 1 of 1:
Item 1: Process Category 1 : General
Item 2: Process Number 2 : Averaging Process
Item 3: User-defined Process Name AvgTemp
Item 4: Input for Average Data S0.1
>
The Averaging Process does use more than the first three standard line items as part of its complete
definition. The fourth line item is a reference to a Sensor Record or preceding Process Record from
which the Averaging Process will calculate an average.
Any Process Record line item that requires a reference to a Sensor Record
or a preceding Process Record is called a Data Input to the process.
Any Process Record line item that requires a numerical value is called a
User Input to the process.
Line Item #4 in the Averaging Process is a Data Input to the process. To specify a reference to data
collected by a particular Sensor Record, the format Sn.m is used. To specify a reference to a data
processed by a preceding Process Record, the format Pn.m is used. for either format, n is the record
index number and m is the data value index number. In our example, you are referencing data collected
by a sensor that collects a single data value. You can use the shorthand format Sn because the only
possible value for m would be 1.
38
In our configuration example, this Averaging Process needs the data collected by the Sensor Record that
is collecting data from the Internal Temperature Sensor. That Sensor Record index number is 1 and it
only collects a single data value. Therefore, you want to type the command C4/S1{ENTER} to
reference the collected Internal Temperature Sensor data. Your screen will look something like this:
38
Refer to Section 10.4.4 for more details.