ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-11
If the user attempts to change any of these parameters while the ZENO
®
-3200 is sampling, ZENOSOFT
®
will return a CCSAIL ERROR 8.
GETPARAMnnn,
Retrieve the value of parameter number nnn from the remote ZENO
®
-3200.
ZENOSOFT
®
will respond with a CCSAIL ERROR 6 if run-time parameter nnn is not valid.
If it is a valid run-time parameter number, ZENOSOFT
®
will respond with the string
PARAMnnn,xxxxx. for example, if ZENO
®
-3200 number 134 is being polled for the current value of
parameter number 2 (the sample time offset in seconds), and if the actual value is 15 seconds, the
following communications will occur.
#01340001GETPARAM2,80^C
#00010134PARAM2,15,02^C
ASCII Run-time Parameters
SETASCIInnn,abcde,
Set the value of the ASCII parameter number
nnn to the string abcde. for example, the third ASCII
parameter is the first modem alarm dial-out phone number. To instruct ZENO
®
-3200 number 329 to
change the first modem alarm dial-out phone number to 555-1212 would require the following command:
#03290001SETASCII3,555-1212,37^C
The ZENO
®
-3200 will respond with a CCSAIL OK if the parameter can be changed successfully.
ZENOSOFT
®
will respond with a CCSAIL ERROR 6 if ASCII parameter nnn is not valid.
ZENOSOFT
®
will respond with a CCSAIL ERROR 7 if ASCII parameter nnn is valid, but data value
xxxxx is out of range.
ZENOSOFT
®
will respond with CCSAIL ERROR 8 if ASCII parameter nnn cannot be changed.
The CCSAIL commands count the ASCII parameters starting from 1, rather than starting from the last
numeric run-time parameter. (In the ZENO
®
-3200 configuration files, the ASCII parameter count starts
from the last numeric run-time parameter). The reason for counting the ASCII parameters from 1, rather
than from the last numeric run-time parameter, is for future compatibility. New numeric run-time
parameters are defined often.
GETASCIInnn,
Retrieve the value of ASCII parameter number nnn from the remote ZENO
®
-3200.