Seitenansicht 149
ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 142
As with downloading Data Records, you can either download the configuration using a simple ASCII-text
dump, or you can use the X-modem file transfer protocol.
165
Coastal Environmental Systems recommends that you use the X-modem file
transfer protocol to download configuration files when your
communications link is prone to noise.
Text Transfer: Enter T{ENTER} in the System Load Menu and the ZENO
®
-3200 will TRANSMIT
the configuration to your computer as a text file. The ZENO
®
-3200 will first prompt you to turn on
your terminal emulation program's text transfer file capture.
> t
Turn On Host Computer File Capture Now.
Enter Any Key To Continue.
Once you have done this, press any key to start the text transfer. You will see the configuration file
as it is transmitted. At the end of the transmission, you will be prompted to stop the text file capture
in your terminal emulation program. Once you have done this, press any key to return to the System
Load Menu.
* Zeno 3200 System Setup File
* Program Version and Date: ZENO-3200 V1.80 compiled: Aug 01 1996 15:53:35
* Copyright (C) Coastal Environmental Systems, 1995, 1996.
* Setup File Date and Time: 96/08/12 19:49:11
PARAM1 3 0 2 2 80 110 1 0 9600 9600 PARAM2 9600 0 0 0 0 1 1 0 0 0
PARAM3 16777 1 60 18 0 4 5 6 2 2 PARAM4 2 2 0 0 1 3276800
PARAM5 0 0 0 0 100 0 0 0 0 0
PARAM6 0 518400 86400 835747200 50336144 151 196608 0 1 0
PARAM7 151 0 1280 18 10000
PARAM8 "NONE" "NONE" "NONE" "NONE" "NONE" "NONE" "" "ZENO"
SENSOR 1 "Temperat" 3 0 0 0 0 0 0 1 0 1 0 1 0 0 0
SENSOR 1 "Battery" 2 0 0 0 0 0 0 1 0 1 0 1 0 0 0
PROCESS 5 8 S1.1 0 1.8 32
PROCESS 1 1 S2.1
DATA 6 1 "<0D><0A>" 1.1 0 0 1
DATA 3 1 "" 1.1 0 0 1
DATA 9 1 "Temp" 1.1 1 0 8DATA 9 1 "Volts" 2.1 1 0 8
* !!SYSTEM TRANSFER COMPLETE.
* Turn Off File Capture Now.
* Enter Any Key To Continue.
EOF
165
The X-modem file transfer protocol was developed by Ward Christensen in 1977 and is a public domain. It is a
simple send-and-wait ARQ (automatic repeat request) protocol using a fixed-length data field and uses either a
simple single-byte checksum or CRC checksum for error detecting. For a complete description of the X-modem file
transfer protocol, refer to pages 100-112 of the book C Programmer's Guide to Serial Communications, 2nd
Edition: Joe Campbell, 1994, Sams Publishing.