Campbell SAT ARGOS Bedienungsanleitung Seite 37

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 394
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 36
ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 29
> H1
* Select Sensor Type Code, valid codes are
- 0 (No Sensor)
- 1 (12-bit Analog to Digital)
- 2 (18-bit Single-Ended A to D)
- 3 (18-bit Differential A to D)
- 4 (Digital Period, f > 10 KHz)
- 5 (Digital Frequency, f > 10 KHz)
- 6 (Digital Period, f < 10 KHz)
- 7 (Digital Frequency, f < 10 KHz)
- 8 (Digital State)
- 9 (Digital Edge)
- 10 (Tipping Bucket)
- 11 (Serial Compass)
- 12 (CCSAIL)
- 13 (SDI-12 Serial)
- 14 (Differential Encoder)
- 15 (GPS Receiver)
- 16 (General Serial)
- 17 (Continuous SDI-12 Serial)
- 18 (Concurrent SDI-12 Serial)
- 19 (Asynchronous CCSAIL)
Hit any key to continue . . .
Our example configuration will use the Internal Temperature Sensor, which is available as a 12-bit ADC
sensor, a Sensor Type Code of 1. So, to configure a 12-bit ADC sensor type for the current Sensor
Record (in this case, Sensor Record #1), type the command C1/1{ENTER} in the Sensor Menu. Once
this is done, the number of line items listed will drastically change, as illustrated below:
> C1/1
SENSOR MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Sensor Items for Record 1 of 1:
Item 1: Sensor Type Code 1 (12-bit Analog to Digital)
Item 2: Sensor Name
Item 3: Sensor Input Channel 8
Item 6: Switched Power Code 0 (NO SWITCHED POWER)
Item 7: Sensor Excitation Voltage Code 0 (NO EXCITATION VOLTAGE)
Item 8: Switched Excitation Return 0
Item 9: Switched Power Warmup Time 0
Item 10: Sensor Sample Count 1
Item 11: Maximum Sensor Readings 0
Item 12: Sensor Timing Loop 1 (0.5 seconds)
Item 13: Conversion Coefficient A 0
Item 14: Conversion Coefficient B 1
Item 15: Conversion Coefficient C 0
Item 17: No. of Additional 15-msec Delays 0
>