Appendix E. CR510PB w/ P190s to CR205s Network
E-5
12: Extended Parameters 4 Digit (P68)
1: 0000 Option ;C
2: 0000 Option ;
3: 0000 Option
4: 0000 Option
5: 0000 Option
6: 0000 Option
7: 0000 Option
8: 0000 Option
13: PakBus - Get/Send Locations (P190)
1: 17 SDC 7
2: 3 Address
3: 26 Get Value
4: 0000 Security
5: 0000 Remote Loc/Coil/Register
6: 1 Swath
7: 9 Local Loc [ CR205Temp_Dat3 ]
8: 10 Result Code Loc [ StatusOfGet3 ]
14: Extended Parameters 4 Digit (P68)
1: 65 Option ;A
2: 105 Option ;i
3: 114 Option ;r
4: 84 Option ;T
5: 101 Option ;e
6: 109 Option ;m
7: 112 Option ;p
8: 95 Option ;_
15: Extended Parameters 4 Digit (P68)
1: 0000 Option ;C
2: 0000 Option ;
3: 0000 Option
4: 0000 Option
5: 0000 Option
6: 0000 Option
7: 0000 Option
8: 0000 Option
16: PakBus - Get/Send Locations (P190); Get CR205 RF Signal Strength
1: 17 SDC 7
2: 3 Address
3: 26 Get Value
4: 0000 Security
5: 0000 Remote Loc/Coil/Register
6: 1 Swath
7: 12 Local Loc [ CR205RF_Stren3 ]
8: 13 Result Code Loc [ StatusOfGet3a ]