Campbell RF410 Bedienerhandbuch Seite 70

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 69
PakBus Networking Guide
64
ROUTER
CR510PB
RF400 Series
PakBus
Address = 20
CR205
PakBus
Address = 30
CR10XPB
(P190 to address 30)
RF400 Series
PakBus Address = 10
strong rf link
strong rf link
long, direct path
weak rf link
Neighbor Filter
Potential Neighbor:
20
Neighbor Filter
Potential Neighbors:
30
10
FIGURE 21. Neighbor Filter Force a Path through Router
7.6 Concurrent Communications
PakBus OSs allow dataloggers to simultaneously communicate with multiple
peripherals using interleaved packet transfers. With an SDC peripheral, packet
arbitration takes advantage of the synchronous device’s addressed enabling. In
the case of a modem enabled peripheral, the datalogger uses a PakCtrl level
“pause”/”finished” exchange to momentarily pause the M.E. peripheral’s link
while another (non-M.E.) peripheral transfers a packet.
As with mixed-array OSs, only one M.E. peripheral can be connected to a
PakBus datalogger. Several SDC peripherals can be connected and
communicating at once. For example, a CR10XPB can connect to: an SC32B
(M.E.), an RF400 (CSDC 7), an MD485 (CSDC 8) and the CR10KD (SDC 6).
They can all be communicating at the same time.
Dual LoggerNet Servers
It is possible to configure two servers in a network, each displaying real time
data on their Numeric Displays. They roughly alternate receiving records from
the datalogger. One server can ring up the datalogger while another sever is
already connected. The key to getting the second server set up is to make sure
that in Options \ LoggerNet Settings (Toolbar) its PakBus Computer ID is set to
a different ID than the first server. To take effect, the ID must be changed
before building the device map. In order to monitor Input Locations in Numeric
Display, once you connect with the second server, it is necessary to Get Table
Definitions by highlighting the datalogger in Setup, clicking on the Data Files
tab, and clicking the Get Table Definitions button.