PakBus Networking Guide
16
and AirTemp_C. The values associated with these will update every 10
seconds which is the scan rate of TEMP_PROBE.CR2.
FIGURE 11. Display of CR205_2 Variables
h. Connect to and view AirTemp_C, etc. in CR205_3.
i. Your PakBus Network is now functioning. You can collect data, send a
different program, or monitor any of the three PakBus dataloggers.
j. With LoggerNet not beaconing, you must connect to CR10XPB_1 to
discover it. CR10XPB_1 has CR105_2 and CR205_3 in its Potential
Neighbor list so it will quickly discover them and make them neighbors.
LoggerNet needs to connect using a static route (from the device map) the
first time it connects to CR10XPB_1. Once LoggerNet communicates with
the CR10XPB it creates a dynamic route and keeps it in its routing table.
3. Choosing a PakBus Network Configuration
3.1 PakBus Overview
3.1.1 PakBus vs. Mixed-array
Mixed-array dataloggers include the older CR10, 21X, CR7 and CR500 and are
programmed using Edlog, however, these do not support PakBus operating
systems (OSs). The CR10X, CR510, and CR23X can be configured as mixed-
array dataloggers but they also accept a PakBus OS because their OSs are
stored in flash memory or Eprom and can easily be changed via CSI’s OS
download utility.