Campbell RF410 Bedienerhandbuch Seite 83

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 82
Appendix B. NL100 TcpServer to RF400 to CR510PB-Router/RF400 to 20 CR205s Network
B-3
CR205 Settings
1. Configure all CR205s with the same Radio Address, Net Address, and
Hopping Sequence using the same settings as the RF400s have.
2. Configure each CR205 with a unique PakBus address (“Datalogger
Address” in PakCom) starting with “1” and ending with “20.”
3. Configure Radio Power Mode = RF_ON
4. Configure Radio Force On = 0
CR510 (Router) Settings
Configure the Network settings, and Neighbor Filter in the CR510PB program
using Edlog\Options\PakBus Settings. When the program is sent to the
CR510PB, the program will configure the PakBus settings in the CR510PB.
FIGURE B-1. Edlog CR510 Setup
The Communication Interval could be set the scheduled collection interval. If
the CR510PB does not hear from a CR205 within 2.5 × this interval, it will
drop the CR205 from its Neighbor List and send hello messages randomly
every 1 to 15 seconds until communications is restored or until you remove the
CR205’s address from the CR510’s potential neighbor list. You could use
PakBusGraph for this.