November 2005, ARM-TR-069
F-1
NL-100 SET-UP
In order to communicate with the NL-100 you need a Null-modem cable and a PC or Laptop with
a terminal communication package. It is assumed for the rest of this document that
HyperTerminal is used. You will also need 12VDC to power the NL-100.
Connect the null modem cable to the PC and the NL-100. You will need a cable with female
connections at both ends. Use gender adaptors if necessary. If this is the first time
communicating with the NL-100 after receipt from factory, go to step 1b.
1a. Open NL-100 by removing four screws. Connect boot jumper across both terminals.
1b. Connect power to NL-100 and connect Null Modem cable.
1c. Open hyperterminal and use following settings:
baud: 115200
databits: 8
parity: none
stop bits: one
flow control: none