November 2005, ARM-TR-069
D-5
Ensure the Communications Enabled
box is checked and leave all settings under hardware tab as
default.
Click on the schedule
tab and change the following settings: ensure Scheduled Collection
Enabled box is checked. Change Collection Interval to 01m, rest 0’s. Change Primary Retry
Interval to all 01m and Number of Primary Retries to 1. Uncheck Secondary Retry Interval and
Collect Ports and Flags. Leave everything else as defaults.
Click on Final Storage Area 1
tab and make the following changes to the settings: check the
Enable for Collections box and change the destination of the data file to the directory created in
step 2 (SurTHRefData) and change the name of the data file to SurTHRef.dat. Uncheck the Use
Default Name box. Under File Output Option,
click the Append to End of File radio button.
Under Output Format,
click the ASCII, Comma Separated radio button. Under Collect Mode,
click on Data Logged Since Last Call radio button and check the Collect All on First Call box.