November 2005, ARM-TR-069
C-5
;R1 probe location
32: Z=F x 10^n (P30)
1: 4 F
2: 0 n, Exponent of 10
3: 38 Z Loc [ R1locate ]
;R2 probe serial number
33: Z=F x 10^n (P30)
1: 92782 F
2: 0 n, Exponent of 10
3: 39 Z Loc [ R2probeSN ]
;R2 probe location
34: Z=F x 10^n (P30)
1: 2 F
2: 0 n, Exponent of 10
3: 40 Z Loc [ R2locate ]
;R3 probe serial number
35: Z=F x 10^n (P30)
1: 92783 F
2: 0 n, Exponent of 10
3: 41 Z Loc [ R3probeSN ]
;R3 probe location
36: Z=F x 10^n (P30)
1: 6 F
2: 0 n, Exponent of 10
3: 42 Z Loc [ R3locate ]
Change the serial number in location 1 (see bold values above) of the appropriate instruction
number for a particular probe or location. For example, if the probe located in V2 was changed
go to Instruction 27 and change the serial number in location 1 of Instruction 27 (0013 above).
The same holds true for moving sensors or changing the location. If the probes in located in V2
and V3 are swapped the serial numbers also have to be swapped in the program.
Once the program has been changed, click on “save” and when the warning banner comes up
asking you to compile click on “yes.” If there are errors or warnings, stop and contact the
mentor(s). If there are no warnings, proceed with loading the program to the data logger. EdLog
can be closed at this time.
Go back to the main LoggerNet menu bar and click on “Connect.” When the “Connect” screen is
active, choose “BBSSRef” from the left hand menu location under Stations. Once the BBSSRef
logger is highlighted, click on the “connect” button under Control. When communication with
the logger has been established (wires connect) click on “Send” under Program. Choose the