Appendix I. Phone to RF401 Series
If there is a neighboring RF401 network, you should change the
Hopping Sequence of base and remote RF401s to a new setting
to avoid interference.
NOTE
- RX LED Test -
To determine if there is a neighboring RF401 network in
operation using the same hopping sequence as yours, stop
communications on your network and observe RF401 green
LEDs for activity. At this point, any green LED activity would
indicate that there is a nearby network using the same hopping
sequence.
3. POINT-TO-MULTIPOINT COMMUNICATIONS (Transparent Protocol)
PC-Modem --------- COM220-A100/PS100-RF401 --------- RF401-DL1
------------ RF401-DL2
LoggerNet SETUP
a. Setup:
ComPort_1
PhoneBase
PhoneRemote
RF401
RF401Remote
CR10X
RF401Remote_2
CR10X_2
b. ComPort_1 – default settings
c. PhoneBase
1) Maximum Baud Rate – 9600
2) Modem Pick List – per PC’s phone modem
3) Extra Response Time – 0 s
d. PhoneRemote – input base site’s phone number
e. RF401 – make Attention Character: “-“ ; leave the rest defaults
f. RF401Remote – make Radio Address: “1“ ; leave the rest defaults
g. RF401Remote_2 – make Radio Address: “2“ ; leave the rest defaults
h. Dataloggers – default settings, schedule collections as desired
RF401 CONFIGURATION
a. Base RF401
1) Active Interface: ME Master
2) Protocol: Transparent
3) CS I/O ME Baud Rate: 9600
4) All other settings: defaults
I-8
Kommentare zu diesen Handbüchern