RF401-series and RF430-series Spread Spectrum Radio/Modems
TABLE 2. Lacking 12 V on CS I/O Pin 8
EQUIPMENT SERIAL NUMBER
CR500 < 1765
CR7 700X Bd. < 2779
21X < 13443
CR10 Wiring Panels All (black, gray, silver)
PS512M Power Supply < 1712
When you connect power to the RF401 (through the SC12 cable or the
optional Field Power Cable) you should see the power-up sequence of red
and green LEDs described in Step 1 (assuming datalogger is powered).
Current dataloggers and wiring panels (not mentioned in Table 2) provide
12 V on pin 8. For older products not listed, check for 12 V between CS
I/O connector pin 8 and pin 2 (GND) or contact Campbell Scientific.
c. Configure the remote radio using the same settings as the base radio (see
“e” in Section 3.2.1). This assumes the base radio is set to AutoSense.
3.2.3 Step 3 – LoggerNet Set-up
a. The next step is to run LoggerNet and configure it to connect to the
datalogger via the radio’s point-to-point or PakBus network you have set
up. For point-to-point and PakBus communications, the radios are
represented as direct connect in LoggerNet (see Figure 4). Refer to
Section 5.2 for the LoggerNet setup of point-to-multipoint.
FIGURE 4. Point-to-Point or PakBus communications, select direct
connect as the connection type.
10