7. Establish communication with the data logger: Select CR1000 on the left and hit the
Connect button on the upper left corner. Once the two are connected you will see the
time ticking on the bottom right corner of the main PC200W window.
8. Clock Synchronization: This is crucial to ensure that all climate data are properly time
stamped. IF YOU FORGET THIS STEP THE DATA WILL HAVE NO VALUE! To
perform the clock synchronization hit the Set Clock button in the clocks area in the main
window of PC200W (see Figure 8 on page 20). MAKE SURE THAT THE CORRECT
LOCAL DATE AND TIME are shown in the Data Logger Field. In locations with
Daylight Savings Time (DST) ensure that the standard time is shown (not the DST time).
Figure 8: Main PC200W window with set clock button highlighted.
3.3 Upload the data collection program
We have created a standardized data collection program that tells the data logger which sensors
are connected where, how often the data is collected, and how it is reported. The program
expects a maximum of five sensors: two temperature/RH sensors, two solar radiation sensors,
and one precipitation sensor. Table 4 shows how different variables from each sensor are
reported as well as for the voltage of the battery and the tachometer reading from the radiation
shield.
Variable (units) Collected every Reported every What is reported
Temperature (
°
C)
5 sec 5 min Average, Standard Deviation
Relative Humidity (%) 5 min 5 min Value at the end of sampling
interval
Rainfall (mm) Continuously 5 min Total
Average Incident
Radiation (W/m
2
)
5 sec 5 min Average, Standard Deviation
Total Radiation (MJ/m
2
) 5 sec 5 min Total