2.8 Level 4 Siting
In many sites it might be difficult to find an open area that complies with the requirements for
Level 1 (siting requirements for all three sensors are met) or Level 2 (siting requirements for
precipitation and temperature are met). In such cases, it is suggested that the station is located in
an open area that is the closest possible match to a Level 2 clearing (see Section 0) and that the
site conditions are carefully documented and monitored annually. In particular, watch for the
following:
• Make sure the Temperature/RH sensor is as far as possible from surrounding vegetation
to minimize microclimatic conditions that could affect the readings.
• Ensure that the precipitation gauge has a clear view of the sky and is as far as possible
from surrounding obstacles to avoid water ‘bouncing in’ from other sources, thus
contaminating the readings.
• Locate the radiation sensor following the guidelines for Level 2 (within 100 m of the
climate station). If this is not feasible, install the radiation sensors as high as possible in
the current climate base and document carefully the site conditions.
• Always document carefully the site conditions and monitor conditions annually.
2.9 Ordering The Equipment
Once an adequate siting strategy has been reached, the appropriate equipment can be ordered.
A standardized list of equipment is shown in Appendix A.1. Allow ample time (minimum of 4
weeks) for the equipment to arrive at customs in the destination country and an additional 4
weeks for clearing the equipment through customs and arriving at their destination.
3 Assembly of the Climate Station
This section describes the whole process of setting up the climate station from the moment the
equipment is received to a full test run of the climate station with all its sensors. The process is
outlined in general with the main steps; for details refer to the instruction manuals accompanying
the base tower, data logger and sensors.
3.1 Testing all the instrumentation upon receipt
Equipment/supplies needed:
• Data logger (CR1000)
• PC200W software (included with data logger)
• Blank memory card
• Battery (UB121000)
• Two Temperature/RH sensors (HMP45C-L)
• Two Solar Radiation sensors (LI200X-L)
• Precipitation sensor (TB4MM-L)
• Computer