Example 1: Temperature Measurements with a Thermocouple
In this example we want to measure temperature using a data logger and a thermocouple as a
temperature sensor. The following paragraphs give step-by-step instructions, assuming that
computer and data logger and power supply are connected correctly.
Supplies:
Desktop or laptop computer
Data logger (CR10X or CR23X)
Several Thermocouple wires (note which type of wire you have)
Flat-head screwdriver
Power supply (12V DC supply)
Communication cables (SC12 for the CR10X or RS232 for the CR23X )
Writing a Data Logger Program
1. Start the program “SCWIN” by double clicking the corresponding icon on the computer
desktop. The following Main Menu (Fig. 1) should appear:
Fig. 1 Main menu of the “SCWIN” program
2. Note only the “Program” button is active. Press the “Program” button and the following
window (Fig. 2) will appear.